VELUX Fixed Skylight with Ventilation Flap Specifications

 

Model FSF
ventilating skylight
104
ventilating skylight
106
ventilating skylight
304
ventilating skylight
308
ventilating skylight
606

W x H W x H W x H W x H W x H
Outside Frame (in) 21-1/2 x
38-1/2
21-1/2 x
46-3/8
30-5/8 x
38-1/2
30-5/8 x
55
44-3/4 x
46-3/8
Finished Frame Dimension (in) 20-1/2 x
37-3/16
20-1/2 x
45-1/16
29-9/16 x
37-3/16
29-9/16 x
53-3/4
43-3/4 x
45-1/16
Rough Opening for EDL/EDW/EDM Flashing (in) 21-1/2 x
39
21-1/2 x
46-7/8
30-1/2 x
39
30-1/2 x
55-1/2
44-3/4 x
46-7/8
Daylight Area-glass (in) 18-3/16 x
32-9/16
18-3/16 x
40-7/16
27-1/4 x
32-9/16

27-1/4 x
49-1/8

41-7/16 x
40-7/16
Daylight Area (sq ft) 4.11 5.11 6.16 9.30 11.64
Ventilation Area (opening) (sq in) 13.30 13.30 19.50 19.50 29.10
Net Weight (lbs) 44 52 58 77 94

 

Model FSF Test Results
 
AIR INFILTRATION
1.57 psf
75 Pa
0.14 cfm/ft2 0.71
l/s/m2
WATER RESISTANCE
9.75 psf
@ 5 US gal/ft2/h
466.5 Pa
@ 3.4 l/m2/min
No Entry No Entry
STRUCTURAL PERFORMANCE

DOWNWARD LOAD WIND UPLIFT
Laminated,
Heat-Strengthened
46-188 (psf) 18-68 (psf)
Laminated, Tempered 72-174 (psf) 23-63 (psf)

THERMAL PERFORMANCE

(Complete unit values)
All thermal performance SHGC Vt values for VELUX® skylights are NFRC certified, labeled and listed in the NFRC product directory. (In accordance with NFRC procedures.)
GLASS
New 20° slope ratings shown
Tempered (75)
Tempered,
Low-E2,
Argon
Gas-filled
Laminated (74)
Laminated,
Low-E2,
Argon
Gas-filled
U-factor (R-Factor)
SHGC
Vt
0.48 (2.08)
0.33
0.55
0.47 (2.13)
0.33
0.54
FADING PROTECTION %
GLAZING CLASSICAL UV
PROTECTION %
TOTAL FADING
PROTECTION %
Tempered(75)
Laminated(74)
87%
99.9%
75%
83%

Return to Non-Venting Page




Copyright @ 1998 - 2009: Accent Building Products - All rights reserved.

Visa
Master Card
Discover Card
American Express
Viladco